Pro3Dure GR-15 gingiva: resin for gingiva masks
Pro3Dure GR-15 gingiva: resin for gingiva masks
Pro3dure GR-15 gingiva is a 3D printing resin for the production of flexible gingiva masks. The material is available in orange-red transparent color.
Pro3Dure GR-15 gingiva: resin for gingiva masks
Pro3dure´s GR-15 gingiva is a 3D printing resin for the production of flexible gingiva masks. Its natural-looking gingival color combined with a gingival-like flexibility allow optimal dental work with a view to ”red and white aesthetics“. The material can be used for build processes with layer thicknesses from 25-100 μm.
COMPATIBLE WITH DLP/LCD/SLA 3D PRINTERS
Technical data
Colour orange red transparent
Density: ca. 1.1 g/ml
Viscosity ca. 2.5Pa s
Post cured material: (depends on postcuring unit)
Hardness: ca. 60 Shore A
Storage between 64°F/18°C and 83°F/28°C
Package 1 kg
Typology 405 nm
Specifications
Property Requirement Result Standard
Tensile Strenght n.a./n.a.* 5 MPa DIN 53505
Elongation at break n.a./n.a.* 90% DIN 53505
Shore Hardness n.a./n.a.* 50A ISO 7619-1
Viscosity (23°C) n.a./n.a.* 2.5 Pa s DIN 53019-1
How to use
GR-15 bottles should be well shaked before use (fig 1).
Make sure that GR-15 material is temperature adjusted up to 23 °C to 30 °C.
Carefully pour GR-15 into the vat of the image projection unit (fig 2).
Bubbles can be removed with a cleaned spatula or by a recoater routine.
If it is possible, always store a bottle GR-15 in your production unit in order to avoid temperature differences during refilling.
For the build parameter adjustment please refer to the machine data sheet.
After the build process is finished a direct post treatment is recommended. If this cannot be done at the time leave the produced objects in the liquid GR-15 gingiva resin.
After cleaning of the parts with isopropanole ≥ 97 % (approx. 3-5 min. in an ultrasonic bath) the objects are postcured in an adequate light curing unit in a protective gas atmosphere.
The dental objects generated out of the generative resin GR-15 gingiva can be repaired with GR-15 gingiva resin.
Impurity due to operation mistakes cannot be excluded. With respect to the low viscosity of the resin it is possible to filtrate the GR-15. It is recommended to filtrate and stir up the resin on a regular base (fig 3).
To avoid bubbles let GR-15 rest for 1 hour before usage.
Important
To avoid detrimental effects on material quality do not expose the liquid material to irradiation under any circumstances.
Deviations from the described manufacturing process may lead to different mechanical and optical properties of the GR-15 material.
Ensure personal protective gear during processing.
Caution: Polymerised resins are chemically resistant -avoid stains on clothing.
Avoid any contact with skin and eyes. In case of accidental contact, rinse with adequate running water, consulting a doctor if necessary.
The lot number and the expiration date are indicated on each bottle of GR-15 gingiva. In case of claims please always indicate the lot number of the product. Do not use the product after expiry of the best before date.